BarriAire™ Gold Extended Bib Particulate Hood

With Nomex® Nano Flex Sure‑Fit™ Panel and Face Opening

39707-00-194071

Now Certified to the NEW NFPA 1970 Standard!
Particulate coverage throughout entire head including Sure‑Fit™ panel at crown and entire extended bib. UL Classified to NFPA 1970: 2025 Standard on Protective Ensembles for Structural and Proximity Firefighting – Current Edition.

Fabric Description:

Quilted composite with PFAS-free durable water resistant finish on the exterior layer and a dual-technology antimicrobial and anti-odor finish on the inside layer with Nomex® Nano Flex between layers for excellent stretch, recovery and odor control. Highest air permeability of particulate fire hoods on the market at 23 cfm, approximately 3-6 times greater than PTFE laminated hoods. Averages 97.4% particulate efficiency for particulates between 0.1 and 1.0 microns. PGI quilted BarriAire composite fabrics recently achieved Viral Filtration Efficiency (VFE) Rating of 96.8% and Bacterial Filtration Efficiency (BFE) Rating of 97.9% (as conducted by Nelson Labs, U.S.A.). NFPA 70E Hazard Risk Category 4.

Sizing:

One size fits most

Options:

Direct Embroidery
100% Nomex® thread embroidered on bib. Minimum order 25 each.
Ink Heat Transfers
High resolution multi-color transfers. Minimum order 100 each.

39707-00-194071 Declaration of Conformity - 2025
39707-00-194071 EU Certificate - 2025

Technology

Videos

Test Results

Fabric Performance ValuesRequirements NFPA 1970
2025 Edition
PGI Test Results
Particulate Efficiency

Quilted Composite

  • Lowest Average as Received
≥ 90% 97.4%
  • Lowest Average after 10 Launderings
≥ 90% 97.3%

Seam at Crown and Panels

  • Lowest Average as Received
≥ 90% 95.5%
  • Lowest Average after 10 Launderings
≥ 90% 98.4%

Seam at Drape Attachment

  • Lowest Average as Received
≥ 90% 95.7%
  • Lowest Average after 10 Launderings
≥ 90% 97.5%
Viral & Bacterial Filtration Efficiency
  • Viral Filtration Efficiency (VFE)
N/A96.8%
  • Bacterial Filtration Efficiency (BFE)
N/A97.9%
Air Permeability (As Received)N/A23 cfm
Thermal Protective Performance (TPP) 20.0 (min) 25.7
Total Heat Loss (THL) ≥ 325 W/m2 379.5 W/m2
Hood Material Burst Strength ≥ 225 N 1352 N
Flame Resistance Test – Quilted Composite

After Flame (Wales x Courses)

  • As Received
≤ 2.0 sec0.3 sec x 0.7 sec
  • After 5 Washings
≤ 2.0 sec1.3 sec x 1.0 sec

Char Length (Wales x Courses)

  • As Received
≤ 100 mm27 mm x 4 mm
  • After 5 Washings
≤ 100 mm7 mm x 3 mm
Cleaning Shrinkage Resistance Test

Hood Measurement

  • After 5 Washings
≥ -5% 0.7%

Face Opening Measurement

  • After 5 Washings
Meets Requirement YES
Heat & Thermal Shrinkage Resistance Test

Hood Measurement

  • As Received
≥ -10%-1.8%
  • After 5 Washings
≥ -10%-0.3%

Face Opening Measurement

  • As Received
Meets RequirementYES
  • After 5 Washings
Meets RequirementYES
Limited Oxygen Index (LOI) Not Required 40
Seam Breaking Strength Test
  • Crown and Panels
≥ 181 N1389 N
  • Drape Attachment
≥ 181 N1139 N
Melt or Drip When Exposed to Flame No Melting or Dripping NONE
Arc Thermal Performance Value (ATPV)46 cal/cm2
NFPA 70E Hazard Risk Category (HRC)HRC 4

Technology

High Magnification Fiber Comparison

Nomex® Nano Flex material consists of nonwoven, submicron, continuous nano-fibers and is inherently flame resistant. It is thinner and lighter weight than typical nonwoven materials. Nomex® Nano Flex is highly breathable and combines exceptional elasticity with superior particulate blocking performance.

Fluorescent Aerosol Screening Test

FAST UV-light photographs without Nomex® Nano Flex (left) and with Nomex® (right) illustrating after particle exposure for the test subject’s head and neck; bright yellow areas show were particles penetrated the ensemble.

Videos

BarriAire™ Gold Burn Tests

The flame protection of PGI's BarriAire™ Gold Rib Knit and 3-Ply Composite is tested at over 2000° F — the results speak for themselves.

DuPont™ Thermo-Man® System

The flame protection of PGI's BarriAire™ Gold hood surpasses the standard 3‑second test under ASTM F1930. This video shows how the BarriAire™ Gold hood stands up to the exponential threat in this 10‑second ASTM F1930 burn.

Donning BarriAire™ Gold Hood - Over Mask

Rib knit completely wraps the face piece, offering better stretch and recovery.

Donning BarriAire™ Gold Hood - In Channel

Designed for optimal fit within the fubber gasket of most SCBA masks.

Product Line

BarriAire™ Gold Particulate Hood

BarriAire™ Gold Hoods

BarriAire<sup>™</sup> Carbon Shield™ Particulate Hood

BarriAire™ Carbon Shield™ Hoods

BarriAire™ Particulate Mask

BarriAire™ Masks

BarriAire™ Comfort Plus Neck Gaiter/Bandanna

BarriAire™ Neck Gaiters/Bandannas

Particulate Protection

BarriAire™ Particulate Barrier Technology products offer more protection, comfort and value. BarriAire™ particulate products combine two layers of proven flame resistant fabric and a middle layer of ultra-lightweight DuPont™ Nomex® Nano Flex fabric which blocks penetration of 97.4% (BarriAire™ Gold quilted composite) to 99.9% (BarriAire™ Carbon Shield™ laminated composite) of harmful submicron size particulates. BarriAire™ Gold quilted composite fabrics recently achieved Viral Filtration Efficiency (VFE) Rating of 96.8% and Bacterial Filtration Efficiency (BFE) Rating of 97.9% (VFE and BFE testing as conducted by Nelson Labs, U.S.A.).