BarriAire Carbon Shield™ Extended Bib Particulate Hood

With Nomex® Nano Flex Sure‑Fit™ Panel and Face Opening

39707-00-192198

Now Certified to the NEW NFPA 1970 Standard!
Particulate barrier coverage throughout entire hood and bib for maximum protection. UL Classified to NFPA 1970: 2025 Standard on Protective Ensembles for Structural and Proximity Firefighting – Current Edition.

Fabric Description:

BarriAire Carbon Shield™ Laminate FR Composite: Carbon Shield™ is a flame resistant fabric breakthrough based on carbon fiber technology. The fabric simply won't burn in air. Besides providing outstanding protection against direct flame, the fabric exhibits low thermal conductivity – making it an excellent insulator against heat. Constructed using advanced patented technology, Carbon Shield™ knit fabric is gravure (dot) laminated to DuPont™ Nomex® Nano Flex, providing the ultimate level of flame, heat and particulate protection without sacrificing breathability or comfort. With a Particulate Filtration Efficiency (PFE) of 99.9% before laundering/conditioning and 98.1% after laundering/conditioning, BarriAire Carbon Shield™ Elite Pro hoods offer superb protection against dangerous and toxic particles routinely encountered while on a working call. Your fire hood is an investment in your health and safety, don't compromise, BarriAire Carbon Shield™ Elite Pro hoods only from PGI.

Sizing:

One size fits most

Options:

Direct Embroidery
100% Nomex® thread embroidered on bib. Minimum order 25 each.
Ink Heat Transfers
High resolution multi-color transfers. Minimum order 100 each.

Test Results

Fabric Performance ValuesRequirements NFPA 1970
2025 Edition
PGI Test Results
Particulate Efficiency

Laminate Composite

  • Lowest Average as Received
≥ 90% 99.9%
  • Lowest Average after 10 Launderings
≥ 90% 98.1%

Seam at Crown and Panels

  • Lowest Average as Received
≥ 90% 98.9%
  • Lowest Average after 10 Launderings
≥ 90% 99.2%

Seam at Drape Attachment

  • Lowest Average as Received
≥ 90% 99.3%
  • Lowest Average after 10 Launderings
≥ 90% 99.6%
Air Permeability
  • As Received
N/A12.26 cfm
  • After 100 Home Launderings
N/A11.60 cfm
Thermal Protective Performance (TPP) 20.0 (min) 26.7
Total Heat Loss (THL) ≥ 325 W/m2 371.6 W/m2
Hood Material Burst Strength ≥ 225 N 611 N
Flame Resistance Test – Laminate

After Flame (Wales x Courses)

  • As Received
≤ 2.0 sec0.7 sec x 0.7 sec
  • After 5 Washings
≤ 2.0 sec0.6 sec x 0.7 sec

Char Length (Wales x Courses)

  • As Received
≤ 100 mm0 mm x 0 mm
  • After 5 Washings
≤ 100 mm0 mm x 0 mm
Cleaning Shrinkage Resistance Test

Hood Measurement

  • After 5 Washings
≥ -5% -2.3%

Face Opening Measurement

  • After 5 Washings
Meets Requirement YES
Heat & Thermal Shrinkage Resistance Test

Hood Measurement

  • As Received
≥ -10%0%
  • After 5 Washings
≥ -10%-0.3%

Face Opening Measurement

  • As Received
Meets RequirementYES
  • After 5 Washings
Meets RequirementYES
Limited Oxygen Index (LOI)
  • Laminate
Not Required 55
  • Nomex® Nano Flex
Not Required 40
Seam Breaking Strength Test
  • Crown and Panels
≥ 181 N639 N
  • Drape Attachment
≥ 181 N596 N
Melt or Drip When Exposed to Flame No Melting or Dripping NONE

Product Line

BarriAire™ Gold Particulate Hood

BarriAire™ Gold Hoods

BarriAire<sup>™</sup> Carbon Shield™ Particulate Hood

BarriAire™ Carbon Shield™ Hoods

BarriAire™ Particulate Mask

BarriAire™ Masks

BarriAire™ Comfort Plus Neck Gaiter/Bandanna

BarriAire™ Neck Gaiters/Bandannas

Particulate Protection

BarriAire™ Particulate Barrier Technology products offer more protection, comfort and value. BarriAire™ particulate products combine two layers of proven flame resistant fabric and a middle layer of ultra-lightweight DuPont™ Nomex® Nano Flex fabric which blocks penetration of 97.4% (BarriAire™ Gold quilted composite) to 99.9% (BarriAire™ Carbon Shield™ laminated composite) of harmful submicron size particulates. BarriAire™ Gold quilted composite fabrics recently achieved Viral Filtration Efficiency (VFE) Rating of 96.8% and Bacterial Filtration Efficiency (BFE) Rating of 97.9% (VFE and BFE testing as conducted by Nelson Labs, U.S.A.).